Live-line Detector

Detects the presence of a live mains conductor

Minimum parts counting

Circuit diagram

Live-line Detector

 

Parts:


  • D1 Red LED (any type)
  • IC1 4017 Decade counter with 10 decoded outputs IC
  • P1 SPST Pushbutton
  • C1 100nF 63V Polyester or Ceramic Capacitor
  • B1 3V Battery (two 1.5V AA or AAA cells in series etc.)
  • Sensing probe__3 to 15 cm. long, stiff insulated piece of wire

Circuit operation:

If the unit is brought close to a live conductor (insulated, and even buried in plaster) capacitive coupling between the live conductor and the probe clocks the counter, and causes the LED to flash 5 times per second, because the 4017 IC divides the mains 50Hz frequency by 10.When remote from a live line, the unit stops counting, the LED resulting permanently off.

Notes:


  • Sensitivity can be varied using a more or less long sensing probe.
  • Due to 3V operation, the LED's current limiting resistor can be omitted.




author: RED Free Circuit Designs
circuit from http://www.redcircuits.com/