A sample and hold circuit, as the name implies, samples an analogue input signal and holds its value until the input is again sampled.
Fig. 1: A typical sample and hold circuit |
When the control terminal is held at logic 1, the switch is closed (on). The time for which the switch remains ‘on’ is called the sampling period (TS). During the sampling period, the hold capacitor (Ch) charges up very quickly through the low ‘on’ resistance of the analogue switch (typically, a few hundred ohms) and follows the analogue voltage at every instant (refer Fig.2).
Fig. 2: Waveforms of input signal, control signal, and sample and hold signal |
During period Th, hold capacitor Ch holds the latest value of the analogue voltage (the value just before the switch is turned off) because it does not find any path to discharge. On the left side it finds the exceedingly large resistance of the ‘off’ CMOS switch (several hundreds of mega-ohms), and on the right side it finds the high input resistance of the buffer (about 105 mega-ohms). So the only path to discharge is its own natural leakage resistance. Using a mylar or teflon capacitor, we can realize a very high leakage resistance in mega-ohms. Thus the voltmeter holds the most recent value of the sampled analogue voltage until we go for the next sampling.
Fig. 3: Capacitor charging circuit and its exponential curve |
The sample and hold circuit can be used to measure a high resistance by charging a capacitor (refer Fig. 3). Initially, the timing capacitor (C) is uncharged. As the pole (P) of the DPDT switch leaves contact 1 and touches contact 2, the output voltage (V) immediately attains the battery voltage (E). (Recall that the voltage across a capacitor cannot be changed instantaneously.) The capacitor now begins to charge up and the voltage V begins to decrease exponentially, viz,
V= E e –t/
where t is the time constant of the R-C circuit, i.e = RC.
Fig. 4 shows the necessary circuit. Here we’ve used National Semiconductor’s IC LF398 (IC2) for the sample and hold circuit. IC NE555 (IC1) is used as an astable multivibrator generating a square wave. Its ‘on’ time is given by:
Ton=RA CT ln2
where ‘ln’ stands for natural log.
This is the previously introduced sampling time (Ts) and is about 0.5 second.
The ‘off’ time of the multivibrator is:
Toff= VRB CT ln2
This is the hold period (Th). Using a 1 mega-ohm linear potentiometer, VRB is adjusted to make Th close to 5 seconds.
Fig. 4: The sample and hold circuit |
First, momentarily press normally-open (N/O) switch S1 so as to discharge hold capacitor Ch and then release it. Keep DPDT switch S2 in Down position, so both the poles are in touch with their respective contact 1. This makes the capacitor C fully discharged and it is ready for placement in the charging circuit.
Fig. 5: The voltage measured at different times |
Carefully observe the blinking of the LED for at least three cycles. Its flashing rate will give you an idea of the sample and hold period. When the LED flashes up for a split second, toggle the DPDT switch to Up position, so both the poles will touch their respective contact 2.
You can now notice the accurate status of the capacitor. The voltage across resistor R is the analogue voltage you want to measure. Measure this voltage regularly at an interval of 5 seconds until the capacitor is fully charged and the voltage across the resistor drops to zero. With C=1 µF and R=22 mega-ohms, it takes about four time constants, which is about 90 seconds for the capacitor to fully charge up.
The natural leakage resistance of the mylar capacitor C is very large and doesn’t contribute in the measurement.